Dubai
Dubai
Sharjah
Abu Dhabi
Al Ain
Ras Al Khaimah
Warehouse
Switchgear
+971-4-2292425 Mon - Sat 08:30 - 19:00 Near Union MS , Deira, Dubai Email: [email protected]

+971-6-5609200 Mon - Sat 09:00 - 20:00 Near Maaza Signal,Ind Area 2 , Sharjah Email: [email protected]

+971-2-6672826 Mon - Sat 08:30 - 19:00 Mussafah 11 , Abu Dhabi Email: [email protected]

+971-3-7333721 Mon - Sat 08:30 - 21:00 Sanaiya 6 , Al Ain Email: [email protected]

+971-7-2210010 Mon - Sat 08:30 - 20:00 Nakheel Rd,Near Safeer Market , Ras Al Khaimah Email: [email protected]

+971-4-3406794 Mon - Sat 08:30 - 19:00 Al Quoz Ind Area 4 , Dubai Email: [email protected]

+971-50-1350347 Mon - Sat 08:30 - 19:00 Deira , Dubai Email: [email protected]

Dubai
Dubai
Sharjah
Abu Dhabi
Al Ain
Ras Al Khaimah
Warehouse
Switchgear
+971-4-2292425 Mon - Sat 08:30 - 19:00 Near Union MS , Deira, Dubai Email: [email protected]

+971-6-5609200 Mon - Sat 09:00 - 20:00 Near Maaza Signal,Ind Area 2 , Sharjah Email: [email protected]

+971-2-6672826 Mon - Sat 08:30 - 19:00 Mussafah 11 , Abu Dhabi Email: [email protected]

+971-3-7333721 Mon - Sat 08:30 - 21:00 Sanaiya 6 , Al Ain Email: [email protected]

+971-7-2210010 Mon - Sat 08:30 - 20:00 Nakheel Rd,Near Safeer Market , Ras Al Khaimah Email: [email protected]

+971-4-3406794 Mon - Sat 08:30 - 19:00 Al Quoz Ind Area 4 , Dubai Email: [email protected]

+971-50-1350347 Mon - Sat 08:30 - 19:00 Deira , Dubai Email: [email protected]

CERTIFIED
IATF 16949:2016
THE BEST
winding wire in U.A.E
PREFERRED CHOICE
for eleCTRICAL PRODUCTS
For Enquiries

LSZH Panel Wire Single Core Flexible (BSEN 50525-3-41)

Category:
Description

Application: 

Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to be protected from further damage resulting from fire. These cables may be installed on, in and beneath the plaster, as well as in closed installation ducts. The direct operating voltages is permitted up to 900 V against ground when they are used in rail-coaches. For the inner wiring of switch boards and distributors these are to be used with an alternating nominal voltage up to 1000V or a direct voltage up to 750V against ground

Standard: 

BS EN 50525-3-41

Technical Data:

Nominal Voltage :H05Z-K Uₒ / U 300 / 500V, H07Z-K Uₒ / U 450 / 750V

Harmonised Designation :0.5 mm2 to 1 mm2 – H05Z-K, 1.5 mm2 to 240 mm2 – H07Z-K

Temperature Range :-15°C to +90°C

Minimum Bending Radius :

Cable diameter ≤ 8 mm : 4 x outer diameter

Approx. diameter > 8 to 12 mm: 5 x outer diameter

Approx. diameter > 12 mm: 6 x outer diameter

Test Voltage : 2500V

Cable Construction:

Conductor :Conductor Class 5 flexible plain/metal coated stranded according to EN 60228

Insulation : Insulation Polyolefin cross linked EI5 to EN 50363-5

Tests:

Smoke density to acc. to EN 61034-2

Halogen free acc. to EN 50525-1, EN 60754-1

Corrosivity acc. to EN 60754-2

Ozone resistant according to EN 60811-2-1

Self-extinguishing and flame retardant according to EN 60332-1-2

LSOH = Low Smoke Zero Halogen-Free